FLUID POWER SYMBOL
TUCSON
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
Umbergaon, Gujarat
C1B 246/5, G.I.D.C. Indl. Estate
tucson@vsnl.com
3D ISOMETRIC VIEW
12
SOLENOID POPPET VALVEDGMSP3
Specifications
Figures based on: Oil Temp = 40°C Viscosity = 40 cSt
Max Flow 30 lpm
Max Pressure 350 bar
Cartridge Material
Working parts : Hardened, ground steel
External surfaces : Zinc plated
Weight DGMSP3 PT: 1.60 kgs
Manifold Material SG Iron
Mounting CETOP3
Seal Kit Number SKDGMSP3 (Nitrile) SKDGMSP3V (Viton
®
)
Filtration Level BS5540/4 Class 18/13 (25µ nominal)
Operating Temp -20°C to +90°C (Standard Seals)
Leakage Less than 0.3 millilitres/min (5 dpm)
Viscosity Range 5 to 500 cSt
Application
The modular or sandwich valve is
stacked along with directional valves
in CETOP 3 interfaces to provide a
poppet valve system. The valve can
be used to dump excess flow to tank
when the system is not in use without
the use of a ‘G’ –spool valve.
Operation
Normally Closed, the valve allows no
flow from P to T. The pilot orifice is
closed and the main poppet seated
due to pressure differential. When
energised, full flow is permitted due to
the pressure difference through the
pilot orifice which holds the main
poppet open.
Features
Sandwich construction offers a
compact solution. Hardened working
parts ensure a long, reliable and
trouble-free life. The cartridg
e
construction gives flexibilit
y in
servicing.
12-390.A
DGMSP3 PT
TP A B
PRESSURE CHARACTERISTICS
TO ORDER
T
UCSON
H
YDROCONTROLS
www.tucsonhydrocontrols.com
tucson@vsnl.com
Umbergaon, Gujarat
C1B 246/5, G.I.D.C. Indl. Estate
Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
12
12-390.B
BASIC CODE
CONTROL LOCATION
PT - From P to T
AT - From A to T
CONTROL LOCATION
BT - From B to T (Only with AT)
SEAL KIT
N: NITRILE
CONFIGURATION
1 - NORMALLY OPEN
2 - NORMALLY CLOSED
DGMSP3 AT 2 BT 2 N H 24
COIL TERMINATION
H - DIN43650
VOLTAGE
24 - 24 VDC
230 - 230 VAC
BASIC CODE: DGMSP3 PT
CETOP3
COMPLETE VALVE
O 5,4 THRO'
4 PLACES
Pressure (bar)
Flow (lpm)
0 10 20 30 40 50 60
0
4
8
12
16
20
48,7
==
46
25
8560,88
BASIC CODE: DGMSP3 AT BT
CETOP3
COMPLETE VALVE
46
60,88 105 60,88
4640
52,5
15,5
CONFIGURATION
1 - NORMALLY OPEN
2 - NORMALLY CLOSED